9
Vermont Castings Vigilant
®
2000898
VIGILANT
24"
(610mm)
Max.
ST687
chimney connector
8/7/01 djt
Prefabricated
Chimney
Single-wall
Chimney Connector
Chimney
Connector
Heat Shield
Bottom
Heat
Shield
ST687
 Chimney connector heat shields may be used to re-
duce clearances when single-wall connectors are used.


When a rear heat shield is used on the stove and a
double wall chimney connector is used, the rear clear-
ance is 15¹⁄₂" (395 mm) and the chimney connector
clearance is 12" (300 mm).



Use of both stove and chimney connector heat shields,
on single-wall connectors, in top-exiting installations
reduces the required clearance. (Fig. 10)
13" (330mm)
18"
(460mm)
ST688
Vigilant
clearances
parallel,
rear heat shield,
chimney connector
heat shield
8/7/01 djt
ST688
 Minimum clearance, chimney connector heat shield,
rear heat shield.

A properly constructed wall shield may be used to
change an unprotected wall to a protected wall, allow-
ing the clearances given in the right half of the Clear-
ance Chart.
Wall shields should be
constructed of 24 gauge
or heavier sheetmetal,
1/2” noncombustible insu-
lation board, or common
brick laid on at (3¹⁄₂" side
down). Shields must be
spaced out from the com-
bustible wall or ceiling 1"
on noncombustible spac-
ers. The spacers should
not be directly behind the
stove or chimney connec-
tor.
Air must be able to ow
between the wall and the
shield. At least one-half
(50%) of the bottom 1"
of the shield should be
open and the shield must
stop 1" from the ceiling.
Protect the top opening
with metal screening to
prevent objects from fall-
ing behind the shield.
Rear wall shields must extend 18" above the top of the
stove or to within 1" of the ceiling, must be centered
behind the stove, and must be a minimum of 48" (1220
mm) wide by 48" high.
Side wall shields must be 48" (1220 mm) wide by 44"
high, and must extend 15" (380 mm) beyond the front
of the stove as measured from a point on the wall that
is on the same plane as the door glass.
ST248
wall shield construction
12/14/99 djt
Air Flow
Wall Shield
Noncom-
bustible
Spacer and
Fasteners
Drywall
Stud Wall Fram-
ing
Air Flow
ST248
 Wall shield con-
struction.